sane-teco2

sane-teco2(5)            SANE Scanner Access Now Easy            sane-teco2(5)

NAME
       sane-teco2 - SANE backend for TECO / RELISYS scanners

DESCRIPTION
       The  sane-teco2  library  implements  a  SANE (Scanner Access Now Easy)
       backend that provides access to some TECO SCSI flatbed  scanners.  This
       backend  should  be considered beta-quality software! TECO scanners are
       sold under various brands like Mustek, Relisys, Piotech, Primax, TRUST.
       This backend may or may not support yours.

       The scanners that should work with this backend are:

                 Vendor Model           TECO model       status
              ----------------------  --------------  -----------
                Mustek ScanMagic 4830S   VM3575        untested
                Primax Jewel 4800        VM356A         good
                Primax Profi 9600        VM6575         basic
                Primax Profi 19200       VM6586         good
                Relisys APOLLO Express 3 VM356A         basic
                Relisys APOLLO Express 6 VM6565         good
                Relisys APOLLO Express 12   ?          untested
                Relisys AVEC II S3       VM3564         good
                Relisys AVEC Super 3     VM3575         basic
                Relisys SCORPIO Pro      VM6575         good
                Relisys SCORPIO Pro-S    VM6586        untested
                Relisys SCORPIO Super 3  VM3575         good

       For  all these scanners, lineart and gray mode work well. However, most
       of them do not support more than a  handful  of  resolutions  in  color
       mode.  See the backend home page (under AUTHOR) for the exact status of
       each scanner.

       Note that the untested scanner will  not  be  directly  supported.  You
       should contact the author for that.

       The  TECO VM number can usually be found at the back of the scanner. It
       is also part of the FCC ID.

       The options the backend supports can either be selected through command
       line  options to programs like scanimage or through GUI elements in xs-
       canimage, xsane, quiteinsane or kooka.

       If you have any success with a scanner not listed here, or if you  have
       any strange behavior, please report to the backend maintainer or to the
       SANE mailing list.

       Valid command line options and their syntax can be listed by using
              scanimage --help -d teco2

       Scan Mode

       --mode selects the basic mode of operation of the scanner valid choices
              are Lineart , Gray and Color The Lineart mode is black and white
              only (1 bit). Gray mode will  produce  256  levels  of  gray  (8
              bits). Color will produce a 24 bits color image.

       --resolution
              Lineart  and Gray selects the resolution for a scan. The scanner
              can do all resolutions between 1 and 600, in increments of 1.

              Color selects the resolution for a scan. The scanner can do only
              the resolutions listed.

              All  values  with ydpi > 300 (300 x 600) or 600 (600 x 1200) re-
              sult in a wrong proportion for the scan. The proportion  can  be
              adjusted with the following imagemagick command: convert -geome-
              try (dpi/max_xdpi * 100%)x100% max_xdpi is for the  vm3575  con-
              stant  with  300  dpi e.g. 600dpi adjust with: convert -geometry
              200%x100%

       Geometry options

       -l -t -x -y
              control the scan area: -l sets the top left x coordinate, -t the
              top left y coordinate, -x selects the width and -y the height of
              the scan area. All parameters are specified  in  millimeters  by
              default.

       Enhancement options

       --custom-gamma (no custom gamma option for the VM3564 and VM356A)
              (color  mode only) allows the user to specify a gamma table (see
              the next 3 parameters).

       --red-gamma-table
              (color mode only) can be used to download a user  defined  gamma
              table for the red channel. The table must be 256 bytes long.

       --green-gamma-table
              (color  mode  only) can be used to download a user defined gamma
              table for the green channel. The table must be 256 bytes long.

       --blue-gamma-table
              (color mode only) can be used to download a user  defined  gamma
              table for the blue channel. The table must be 256 bytes long.

       --white-level-r
              (VM3564,  VM356A, VM3575 and VM6575 only) Selects what red radi-
              ance level should be  considered  "white",  when  scanning  some
              sheets  by  changing the calibration value loaded into the scan-
              ner. Scale 0..64 in steps of 1.

       --white-level-g
              (VM3564, VM356A, VM3575 and VM6575 only) Selects what green  ra-
              diance  level  should  be considered "white", when scanning some
              sheets by changing the calibration i value loaded into the scan-
              ner. Scale 0..64 in steps of 1.

       --white-level-b
              (VM3564, VM356A, VM3575 and VM6575 only) Selects what blue radi-
              ance level should be  considered  "white",  when  scanning  some
              sheets  by  changing the calibration value loaded into the scan-
              ner. Scale 0..64 in steps of 1.

       --preview
              requests a preview scan. The resolution used for that scan is 50
              dpi (for VM356A and VM6575 75 dpi) and the scan area is the max-
              imum allowed.  The scan mode is user selected.  The  default  is
              "no".

CONFIGURATION FILE
       The  configuration file @CONFIGDIR@/teco2.conf supports only one infor-
       mation: the device name to use (eg /dev/scanner).

FILES
       @LIBDIR@/libsane-teco2.a
              The static library implementing this backend.

       @LIBDIR@/libsane-teco2.so
              The shared library implementing this backend (present on systems
              that support dynamic loading).

ENVIRONMENT
       SANE_DEBUG_TECO2
              If the library was compiled with debug support enabled, this en-
              vironment variable controls the debug level  for  this  backend.
              E.g.,  a  value  of 128 requests all debug output to be printed.
              Smaller levels reduce verbosity.

       SANE_TECO2_CAL_ALGO
              Either 0 or 1. Selects the  algorithm  for  the  calibration.  A
              value  of  1  seems  to give better scans on the VM356A, VM3575.
              Feedback on it is welcome.  For VM3564, VM356A,  VM3575,  VM6575
              default 1.  For other supported types default 0.

LIMITATIONS
       The  windows TWAIN driver has many more options than this SANE backend.
       However they are only software adjustments. This  backend  only  imple-
       ments what the scanner can support.

BUGS
       Plenty. Parts of this backend are still under development.

SEE ALSO
       sane-scsi(5), scanimage(1), xscanimage(1), xsane(1), sane(7)

AUTHORS
       Frank Zago
              http://www.zago.net/sane/#teco2

       The package is actively maintained by Gerard Klaver.
              http://gkall.hobby.nl/teco2.html

CREDITS
       Thanks to:

       Gerard  Klaver  for  his  relentless  VM3575 testings and contributed a
       patch to support the VM3564 and VM356A.

       Mark Plowman for providing the first SCSI traces from a VM3575.

       Andreas Klaedtke for providing the first SCSI traces from a VM6586  and
       for his testing, and to Stefan von Dombrowski for his testing.

       Nicolas  Peyresaubes  for providing the first SCSI traces from a VM656A
       and for his testing.

       Dave Parker for testing the support for the VM6575.

       Michael Hoeller for testing the support for the VM356A.

       Christoph.Hoeffner for testing the support for the VM3564 (Relisys AVEC
       II S3 firmware 1.09).

@PACKAGEVERSION@                  14 Jul 2008                    sane-teco2(5)
Man Pages Copyright Respective Owners. Site Copyright (C) 1994 - 2024 Hurricane Electric. All Rights Reserved.