sane-snapscan
sane-snapscan(5) SANE Scanner Access Now Easy sane-snapscan(5)
NAME
sane-snapscan - SANE backend for AGFA SnapScan flatbed scanners
DESCRIPTION
The sane-snapscan library implements a SANE (Scanner Access Now Easy)
backend that provides access to AGFA SnapScan flatbed scanners. At
present, the following scanners are supported from this backend: AGFA
SnapScan 300, 310, 600, and 1236s, 1236u, 1212u, e20, e25, e40, e50,
e60, Vuego 310s, Acer 300f, 310s, 610s, 610plus, Prisa 620s, Prisa
620u, Prisa 620ut, Prisa 640u, Prisa 640bu, Prisa 1240, Prisa 3300,
Prisa 4300, Prisa 5300 and Guillemot Maxi Scan A4 Deluxe (SCSI) (with
varying success).
DEVICE NAMES
This backend expects device names of the form:
special
Where special is the path-name for the special device that corresponds
to a SCSI scanner. For SCSI scanners, the special device name must be a
generic SCSI device or a symlink to such a device. Under Linux, such a
device name could be /dev/sga or /dev/sge, for example. See
sane-scsi(5) for details.
For USB scanners the devicename must contain the keyword "usb", as in
/dev/usbscanner or /dev/usb/scanner0. For scanners that need a
firmware upload before scanning add a line starting with "firmware"
followed by the fully qualified path to your firmware file, e.g.
firmware @DATADIR@/sane/snapscan/firmware.bin
For further details read http://snapscan.sourceforge.net.
CONFIGURATION
The contents of the snapscan.conf file is a list of device names that
correspond to SnapScan scanners. Empty lines and lines starting with a
hash mark (#) are ignored. See sane-scsi(5) on details of what consti-
tutes a valid device name.
FILES
@CONFIGDIR@/snapscan.conf
The backend configuration file (see also description of
SANE_CONFIG_DIR below).
@LIBDIR@/libsane-snapscan.a
The static library implementing this backend.
@LIBDIR@/libsane-snapscan.so
The shared library implementing this backend (present on systems
that support dynamic loading).
ENVIRONMENT
SANE_CONFIG_DIR
This environment variable specifies the list of directories that
may contain the configuration file. Under UNIX, the directories
are separated by a colon (`:'), under OS/2, they are separated
by a semi-colon (`;'). If this variable is not set, the config-
uration file is searched in two default directories: first, the
current working directory (".") and then in @CONFIGDIR@. If the
value of the environment variable ends with the directory sepa-
rator character, then the default directories are searched after
the explicitly specified directories. For example, setting
SANE_CONFIG_DIR to "/tmp/config:" would result in directories
"tmp/config", ".", and "@CONFIGDIR@" being searched (in this or-
der).
SANE_DEBUG_SNAPSCAN
If the library was compiled with debug support enabled, this en-
vironment variable controls the debug level for this backend.
E.g., a value of 255 requests all debug output to be printed.
Smaller levels reduce verbosity.
BUGS
Man page doesn't provide much information yet.
SEE ALSO
sane(7), sane-scsi(5)
http://www.cs.ualberta.ca/~charter/SnapScan/snapscan.html
http://sourceforge.net/projects/snapscan/ (new development website)
AUTHOR
Kevin Charter, Franck Schneider, Michel Roelofs, Emmanuel Blot, Mikko
Tyolajarvi, David Mosberger-Tang, Wolfgang Goeller, Petter Reinholdt-
sen, Gary Plewa, Sebastien Sable, Oliver Schwartz and Mikael Magnusson.
Man page by Henning Meier-Geinitz (mostly based on the web pages and
source code).
@PACKAGEVERSION@ 14 Jul 2008 sane-snapscan(5)